Blog

How to Specify commercial displays for system integrators

Nov 16, 2026

An integrator's bill of materials lives or dies on the display line. The panel sets the mounting pattern, the power budget, the network path, the content workflow and the service call schedule — long after the software team has moved on to the next project. If you are specifying commercial displays for a customer installation, the job is not to pick a screen size. It is to write a specification that survives procurement, site installation and three years of operation.

This guide walks through the decisions every integrator has to make, shows how each one maps onto real hardware categories, and closes with the enquiry checklist we ask buyers to fill in before we quote.

Start from the mounting method, not the screen size

Screen size is the easiest number to change late. Mounting method is not. Before you shortlist anything, decide how the display physically attaches to the site:

  • VESA embedded into a cabinet or machine face. You are buying an open-frame or panel-PC module that your enclosure team cuts into. The VESA pattern (75×75 mm or 100×100 mm) and the cut-out dimensions become part of your mechanical drawing, so they must be locked before the sheet-metal work starts.
  • Wall-mounted against finished surface. Confirm wall construction, load path and where power and data enter the wall. Wall-mounted signage usually needs a service gap for port access.
  • Free-standing kiosk on a floor. Footprint, anchoring and anti-tip requirements come from the venue, not from the display vendor.
  • Bolted to existing retail furniture such as gondola shelving. Here shelf edge thickness, daisy-chain power and cable routing along the fixture decide whether the deployment is tidy or a call-back.

Pick the mounting method first and the product family sorts itself out. Our embedded touchscreens and industrial touchscreen panel PCs cover the cut-in case; wall-mounted digital signage displays, indoor kiosks and outdoor displays cover the rest.

Specify the environment as numbers, not adjectives

"Rugged" and "industrial grade" mean nothing in a purchase order. Write down four values and hold the supplier to them:

  • Ingress protection for the exposed face. A washdown area or a factory floor needs an IP65-rated front with tempered glass. An enclosed lobby does not, and paying for it buys you weight and cost only.
  • Operating temperature range. Cold-store entrances, machine rooms and un-air-conditioned arcades sit outside the comfort range of office monitors.
  • Brightness in cd/m². Indoor signage under normal shop lighting is served by around 350–500 cd/m². Anything facing daylight needs a different class of panel entirely.
  • Cooling method. Fanless designs have no moving parts to clog with dust and run silent, which matters in clinics, classrooms and cleanrooms. Actively cooled enclosures are the normal choice for high-brightness outdoor units that have to shed real heat.

Two examples from our catalogue show how one supplier's range spans both ends of that specification. The 15 Inch Industrial Panel PC – VESA-Mounted Embedded is documented with a 3 mm tempered glass front at IP65, an IP40 back case, fanless aluminium housing and a −10 °C to 50 °C operating range — the profile you would write for a control panel or an HMI station. At the other end, the 43 Inch Outdoor Android Kiosk is listed at IP65 with 2500 cd/m² and a built-in light sensor for automatic brightness adjustment, which is the specification you need when the panel competes with direct sun.

One habit that saves rework: never accept a single combined rating where the datasheet distinguishes front protection from back-case protection. For embedded work the front rating is what your customer's cleaning and dust exposure actually touches, while the rear sits inside a cabinet.

Choose touch technology against the user, not the budget

If the display is passive signage, skip this section. If a person puts a finger on it, touch technology becomes a project risk:

  • Projected capacitive (PCAP) gives a glass-fronted, sealed surface that is easy to wipe down and supports multi-touch. On industrial models the response time is quoted in milliseconds, and some are documented as glove-compatible — relevant for production lines and food processing, where bare-finger touch is not an option.
  • Infrared (IR) frames sit proud of the glass and tolerate almost anything placed on the screen. They suit large-format interactive surfaces in very high-traffic public installations, at the cost of a raised bezel that collects debris.
  • No touch at all is the correct answer for wayfinding walls and menu boards where the software is kiosk-mode playback. Every touch layer you add is another item to calibrate and replace.

Where interactivity matters, compare like for like in your enquiry: touch technology, number of touch points, whether the surface accepts gloves or a stylus, and whether the glass is anti-glare. A 32 Inch Commercial Wall-Mounted Android Touchscreen with an IP65-rated tempered glass front and fanless cooling is a common pick for self-service in retail and hospitality; the 55 Inch Commercial Windows Infrared Touchscreen Kiosk points the other way, where a large IR interactive surface on Windows is what the customer's application already runs on.

Decide where the computing lives

Three architectures cover almost every deployment, and each one changes what you order:

ArchitectureBest whenWhat you specify
Monitor plus external player or PC The client already owns a CMS, or the content source is a machine, PLC or existing PC on site. Video inputs (HDMI, DisplayPort, VGA), power input range, VESA pattern for hiding the player behind the panel.
Android all-in-one display Stand-alone signage or a light interactive app, single network drop, no local IT support at the site. Processor, RAM and storage, WiFi/Ethernet/Bluetooth, OS version, CMS player compatibility.
Panel PC (display and computer in one sealed unit) The screen is also the operator interface for an application: SCADA visualisation, production reporting, queue management, self-ordering. Processor class, RAM and solid-state storage, I/O set including RS232 for legacy devices, fanless design, front IP rating.

There is a fourth option integrators under-use: retrofit an existing monitor with a VESA-mounted Android media player. The RK3568 Android Mini PC is a fanless, VESA-mountable unit with Ethernet, USB, RS232 and HDMI output, expansion options for cellular modules, and support for both Android and Linux — useful when your customer's software team wants Linux but the site only has a spare wall-mounted screen. For multi-screen or high-resolution content, the higher-end RK3588 boards in the same family carry the decode load.

Field rule of thumb: if the display sits behind glass in a shopfront and nobody maintains that site, put the compute inside the display. Every separate box is another failure point someone has to climb a ladder to reach.

Match the format to the physical gap you have

16:9 is not the only aspect ratio worth specifying, and forcing a standard panel into a narrow space is how projects end up with dead bezels and unhappy store managers. Bar-format and stretched panels exist precisely for the gaps normal screens cannot fill:

  • Shelf-edge and pricing strips. The Commercial Shelf Edge LCD Series is built for integrators deploying electronic shelf labels at scale: an ultra-wide bar panel with CMS and API integration, ERP/POS price synchronisation, daisy-chain power and data, and shelf brackets that clamp to common fixture edge thicknesses. Mixed lengths across one store are managed from a single platform, so a rollout can use different sizes aisle by aisle.
  • Retail strip screens for gondolas and fixtures. Ultra-wide stretched LCD displays run along a fixture face where a normal panel would block the product.
  • Square and circular panels for column wraps, end-caps and feature installations where shape is part of the design language.

When you specify a bar-format panel, ask for the physical length in millimetres as well as the diagonal. Aisle fixtures are sold in standard metre lengths, and the mounting brackets have to match the fixture, not the marketing size.

Lock integration and service terms before the order

This is where integrators lose margin. The panel arrives on time, works on the bench, and then the site reveals what nobody wrote down:

  • Ports and legacy devices. Card readers, scales, PLCs and receipt printers still talk RS232. Confirm serial is present rather than assuming an adapter will do.
  • Power input range and plug type per country. Wide-range AC inputs are standard, but the cord set and regional plugs need to be in the order line, not improvised by the installer.
  • Network path. Wired Ethernet for anything you manage centrally; WiFi only where a cable genuinely cannot be run, with an external antenna on metal or glass installations.
  • CMS and API access. If your software has to schedule content, read device health or push price updates, confirm the player supports your platform or exposes an API before you commit to volume.
  • Certification scope for the destination market. UL/FCC for North America, CE for Europe, CCC for China — and check the certificate covers the exact model number you are ordering, not just the product family.
  • Spare units and service route. Order spares with the deployment. A single failed panel in a multi-store rollout is an emergency procurement at premium pricing.

The enquiry block to copy into your next request for quotation

A supplier quotes faster and more accurately when the enquiry already answers these. Send it as a list:

  • Application and industry, with one sentence on what the customer sees on screen.
  • Installation environment: indoor or outdoor, ambient temperature range, direct sunlight or shaded, cleaning regime.
  • Mounting method and required VESA pattern or cut-out dimensions; for retail fixtures, edge thickness and available run length.
  • Screen size range and aspect ratio, including whether a bar-format panel is acceptable.
  • Brightness target in cd/m² and whether anti-glare glass is needed.
  • Touch required or not; technology, touch points, gloves or stylus use.
  • Compute: monitor only, Android all-in-one, panel PC, or external media player — plus processor, memory and storage if the application is known.
  • Required ports, network type, and any peripherals to integrate.
  • CMS or software platform in use, and whether API access is required.
  • Quantity, phased delivery dates, destination country, and certification scope.

Send those ten lines and you will get a comparable quotation back rather than a catalogue. That is the difference between specifying commercial displays as a line item and specifying them as part of a system your customer can actually run.

For project sourcing, customization and volume pricing on any of the families above, talk to our engineering team through the contact page, or read how we handle OEM and ODM display manufacturing and custom commercial display projects. If you resell display hardware, our distributor programme covers stocking and support terms.